Waster water /river/lake
In waste water industry , river or lake related areas , we suggest that you can choose the following sensors:
pH sensor
· Direct use with various pH meters as a complete set.
· Installation with 3/4NPT pipe thread, with safe and reliable sealing.
· Convenient to installation in form of flow-through or immersion.
· The sensor has the fixed cable and the length of the cable can be adjusted according to the
requirements of the users.
· pH range:0-14; zero point: E0=7pH; Temperature rang: 0-110℃.
· Pressure range:0.6MPa.
· The external dimension of the sensor isΦ26×165.
· The outer tube material: PPS plastic.
Selection of model:
· PCA2121 two in one combination sensor
· ASPSA2121 three in one combination sensor ,Please note the value of the thermistor
when order:Pt100、Pt1000、2.252K、10K、22K etc.
ORP sensor
· It can be directly used together with various redox meters as a complete set.
· Installation with 3/4NPT pipe thread,convenient to installation.
· The sensor has the fixed cable.
· The length of the cable can be adjusted according to the requirements of the users.
· Measuring range:±2000mv.
· Temperature rang: -10-110℃.
· Pressure range:0.6MPa.
· The external dimension of the sensor:Φ26×165mm.
· The outer tube material:PPS plastic.
Selection of model:
· ASRS2801 combination ORP sensor (Pt ring)
· ASRS2501 combination ORP sensor (Pt pin)
· It can be installed with the thread 3/4NPT.
· The sensor has the fixed cable and the length of the cable can be adjusted according to
the requirements of the user.
· Suitable for the industries such as water, wastewater treatment, aquaculture and so on.
· Measuring range: 0ppm~saturation, 0.1%~200%.
· Temperature rang: 0~80℃.
· Pressure range:0.4MPa.
· The external dimension of the sensor :Φ25×165.
· The outer tube material:PPS plastic.
· The thermistor is Pt100、Pt1000、2.252K、10K、22K etc.
Selection of model:
· ASY2121(polarographic)
· ASYY2121(galvanic)
____________________________________________________________________________________________________________
· It is a digital fluorimetric oxygen sensor
· It is a digital sensor with predictive diagnostic function that converts the analog signal directly to
digital signal
· Data is stored
in the sensor interface
· Can be calibrated in the laboratory, take the field plug and display, the system automatic
identification, without on-site calibration of the
electrode, easy to use
· No need a DO transmitter, the sensor can output digital signal and the digital signal can be
transport to the computer
· The output digital signal can be directly converted into WIFI or GPRS signal to achieve wireless
transmission
· Data can be
transmitted over short distances or long distances
· The measured
value is stable and reliable
· Measuring range:
0-50mg/L; Measuring accuracy: ±0.1mg/L; Resolution: 0.01mg/L
· Dimensions:
?25*165mm
· Temperature
range: 0-55℃; Measuring
accuracy: ±0.1℃; Resolution: 0.1℃
Selection of model:
· ASYF2121D